SkyRC OSH Six-Port 1S Hub: Why Jumper Placement Matters
A pilot connects six 1S BT2.0 batteries to a SkyRC OSH hub and plugs the hub into a B6neo-family charger. The charger reports a cell-count or connection error, even though every individual battery charges normally. The first question is the OSH jumper-cap position: SkyRC specifies that the jumper must be installed on the pins corresponding to the actual occupied 1S cells, and that the jumper is installed before connecting the batteries. A hub with six physical sockets should not be treated as a charger that automatically detects every partial-slot configuration.
What SkyRC OSH actually does
The SkyRC OSH 6-Port 1S BT2.0 Charging Hub is an accessory for compatible SkyRC B6neo, B6neo 2, B6neo+, and B6ACneo chargers. It provides six 1S battery sockets through an XT60 charger-side connection and balance interface. SkyRC specifies compatibility with LiPo, LiHV, Li-ion and LiFe battery chemistries when the correct charger mode is selected. This unit is the BT2.0 variant; SkyRC also sells a physically different PH2.0 socket variant.

| SkyRC specification | Documented value | Why it matters |
|---|---|---|
| Supported chargers | B6neo, B6neo 2, B6neo+, B6ACneo | Not a universal standalone USB-C charger |
| Battery chemistry | LiPo, LiHV, Li-ion, LiFe | Select the correct final voltage and algorithm in the charger |
| Battery sockets | 6, BT2.0 on this SKU | PH2.0 is a separate product variant |
| Published maximum output current | 2.0A | Do not assume every socket independently supports 2A |
| Jumper | Position according to connected cell count | Incorrect setup can cause charging errors or damage |
| Physical size / mass | 50.5×39×34.5mm / approx. 20g | Bench placement and charger support |
Why six 1S packs require more care than six USB chargers
The OSH is a passive charging/balance interface controlled by the main SkyRC charger, not six independent charger ICs. The main charger uses battery chemistry, series-cell count and its balance circuitry to supervise the connected arrangement. Therefore, occupied position and jumper placement matter. A physical XT60 connection alone does not define which cell positions are populated, and the six ports should not be randomly occupied while the charger is already delivering current.
SkyRC’s original instruction manual emphasizes the correct order: insert the jumper cap first, aligned with the intended cell positions, and then connect the 1S batteries in the illustrated sequence. Do not invent a shortcut by bridging arbitrary pins, using a jumper on the wrong row or copying a vague diagram from a different six-port charging board. Read the exact OSH label and original instruction diagram for each occupied-battery count.
LiPo versus LiHV: a voltage mistake can ruin small packs
A typical ordinary 1S LiPo charges to 4.20V per cell; a supported 1S LiHV pack may specify 4.35V. Do not select LiHV mode for an ordinary LiPo battery merely because a higher charge voltage sounds like additional runtime. Likewise, the hub itself does not automatically convert a LiPo to LiHV or override the battery manufacturer’s voltage limit. Verify the actual label and chemistry of each pack before putting them in one charging session.
Different battery chemistries, capacities, health or very different starting voltages should not be casually combined in an unverified shared arrangement. Use only a manufacturer-supported set of compatible batteries in the correct slots. If one pack is swollen, punctured, overheated or has a damaged BT2.0 contact, keep it out of service and do not force a charge through the hub.
Six common charger errors and their causes
| What you see | What to investigate |
|---|---|
| Cell count inconsistent with connected batteries | Wrong jumper position, missing pack or misplaced occupied slot |
| Balance connection error | Hub balance interface, jumper alignment or incorrect connection sequence |
| One slot does not appear to charge | Damaged BT2.0 socket, bad pack or occupied-position error |
| Charger stops immediately | Pack chemistry/mode mismatch, input supply or connection fault |
| One battery gets warm unusually fast | Cell damage, contact resistance or unsuitable charge current |
| PH2.0 pack cannot be inserted | Wrong OSH variant—BT2.0 and PH2.0 require the intended connector |
A safe operating workflow
- Power and inspect: identify the B6neo-series charger, genuine OSH hub and BT2.0 version; check cables, pins and battery connectors with the charger output inactive.
- Identify each pack: verify it is a supported 1S chemistry and its manufacturer’s charge voltage/current specification. Do not mix visibly damaged packs.
- Read the original jumper diagram: select the correct occupied-cell arrangement and insert the jumper into the specified pin position before plugging batteries into the hub.
- Connect batteries in the documented order: use the exact numbered slots for the selected arrangement, and do not leave an unaccounted gap.
- Configure the charger: select correct chemistry, cell-count arrangement and a conservative current within the hub’s 2.0A maximum and each battery’s safe charge limits.
- Start and supervise: observe pack voltage and cell readings for agreement, stop for error messages, excessive heat or voltage divergence and never leave LiPo charging unattended.
- Power down before rearranging: stop the charge, disconnect the source through the approved sequence and then move the jumper or batteries—never reconnect live packs during an active balancing session.
Why the 2A rating should not be multiplied by six
The official SkyRC product specification says “Output Current: Max. 2.0A.” It does not say “2A per socket simultaneously, six times.” Current through a multi-cell charger interface is governed by the main charger and wiring topology. A user calculating six times 2A and programming 12A simply because there are six physical sockets risks overloading the hub or small packs. Follow the manual’s actual connected-cell and current guidance rather than treating the product as six independent 2A chargers.
BT2.0 or PH2.0?
Choose the exact connector used by the battery. BT2.0 and PH2.0 can serve similar 1S micro aircraft but are not identical plug shapes or contact designs. A forced connector or low-quality improvised adapter may introduce resistance and heating, especially with tiny packs. If a fleet contains both styles, organize appropriately rated separate charging hardware or verified manufacturer-supported adapters rather than forcing battery plugs into the wrong OSH variant.
Sources and correct charging hardware
SkyRC’s official OSH 6-Port 1S product page lists the chemistry, supported chargers, BT2.0/PH2.0 variants, 2.0A limit and jumper requirement. Consult SkyRC’s original downloadable OSH instruction manual and jumper diagram before setting occupied slots. The BT2.0 version sold by FalconFly is the exact item covered here. For chemistry selection, see our 1S whoop battery LiHV and connector guide.