iMars D300 Plus Discharges LiPo Slowly: Why 700W Charging Is Not 700W Discharging
You bought a dual-channel charger advertised at up to 700 W DC charging, but putting a large LiPo pack into storage mode takes ages. That can be normal. Charging power, internal discharge power and any supported external discharge arrangement are separate specifications, and mixing them up creates unrealistic expectations.
The headline charging number is not a discharge rating
Gens Ace lists iMars D300 Plus with high-power charging capacity—up to 300 W AC total and 700 W DC total on the specified configuration—while its published internal discharge specification is 15 W per channel. The difference exists because internal discharge must turn removed battery energy into heat the charger can safely handle.
Charging and discharging therefore operate under different power, current and thermal limits. A charger capable of filling a pack rapidly can still need a long time to bring the same pack down to a safer storage level.
Estimate the time from energy, not just amperes
A rough energy-change estimate is pack voltage times ampere-hours removed. For example, removing 25 Wh of energy using a charger that can dissipate at most 15 W requires at least 1.7 hours in ideal conditions; the real result may be longer because voltage falls and current/power management changes. The estimate scales across each channel separately.
Do not assume the pack starts with all nominal energy still available. A partially used battery needs less discharge than a fully charged one. The battery’s actual voltage and the selected storage target determine how much energy must be removed.
Read the charger display correctly
In a discharge session the charger may limit current to stay within its 15 W internal power envelope. As pack voltage changes, the current corresponding to the allowed power also changes. Temperature protection may reduce performance further. If one channel is unexpectedly idle, check that the correct mode started and the charger sees a valid cell count and balance connection.
The published output rating for charging does not apply in reverse. Some devices support dedicated external discharge functions or other operating modes, but those require exact manufacturer-approved accessories and limits.
| Metric | iMars D300 Plus spec | Meaning |
|---|---|---|
| AC charging | 300 W total | Maximum charge power on mains |
| DC charging | 700 W total | Maximum charge power on suitable DC source |
| Internal discharging | 15 W per channel | Heat-dissipation bound on discharge |
| Discharge current | Up to 3 A per channel | Current cap; power cap may limit first |
Why storage mode exists
LiPo and LiHV batteries should not normally be stored fully charged for long periods; battery care recommendations depend on chemistry, pack design and manufacturer. Storage mode brings cells toward the charger-supported target in a controlled manner. This improves handling discipline but does not make a damaged or swollen pack safe.
For fast-paced FPV sessions, plan the number of fully charged packs around expected use instead of fully charging excessive spare inventory. This reduces the number of packs needing a lengthy storage discharge after flying.
When to buy a different discharge solution
If you routinely manage dozens of 6S packs, compare equipment specifically designed for high-power discharge and manufacturer-approved energy recovery rather than expecting a general two-channel charger to absorb hundreds of watts. Check connector ratings, thermal safeguards, pack compatibility and real-world duty cycle. A different charger is not necessarily the answer if it has the same internal discharge limit.
Document the workflow and remove any pack with abnormal temperature, swelling or cell-voltage behavior from ordinary charging/discharging operations.

Understand the actual Gens Ace numbers
The official Gens Ace iMars D300 Plus specifications distinguish charge and discharge capabilities. AC charging is rated up to a combined 300 W, while DC charging on a suitable external source can reach a combined 700 W, expressed as 350 W per channel. Charging current is listed up to 16 A per channel within the charger’s other limits. In contrast, internal discharge is specified at 15 W per channel with a maximum discharge current of 3 A per channel. Those are not contradictory figures: they describe different jobs performed by different electrical paths.
During charging, energy comes from mains or a DC supply and enters the battery. During internal discharge, the charger takes energy out of the battery and usually dissipates much of it as heat. The amount of heat the compact device can manage safely is limited, which is why the internal discharge-power rating is far smaller than its input-powered charging rating. A 700 W headline does not imply the charger can absorb 700 W from a battery.
Always use the exact manual and current product revision. Similar iMars names may have different charge/discharge capabilities, ports and channel counts. A buyer choosing between compact and multi-channel chargers should compare the discharge specification explicitly if storage preparation is an important part of the workload.
Calculate a discharge estimate rather than guessing
Energy is measured in watt-hours. An approximate lower bound on discharge time is energy to be removed divided by the device’s available discharge power. If a pack needs to lose 30 Wh and the charger can internally dissipate up to 15 W on that channel, the ideal minimum is two hours. The actual process can take longer because cell voltage changes, maximum current may be reached at some points, temperature protection may limit output and the algorithm may taper near the storage target.
Suppose a large 6S flight pack has been fully charged but the shoot is cancelled. The charger may spend a long time reducing it to storage level. There is no need to force a higher current than the 15 W power limit permits. Current equals power divided by voltage, so a 15 W limit at approximately 24 V implies about 0.625 A, below the charger’s separate 3 A maximum current specification. The current reading can therefore be much less than 3 A while the device is operating exactly as designed.
Do not apply a time estimate without checking battery chemistry, actual starting voltage and the required storage target. The amount of energy removed varies, and a pack that has already been used in a flight may need little or no discharge. Use the charger display and battery manual rather than a generic storage-voltage shortcut copied from another chemistry.
Why slow storage discharge is not necessarily a fault
A charger can maintain stable voltage readings, balance cells and operate within its thermal limits while taking hours to complete discharge. That is consistent with a low internal power rating. Look for actual error messages, impossible cell readings, interrupted balance connections or overheating before concluding it is defective. The charger may also pause or change current as its protection system responds to conditions. Respect the operating temperature range and keep ventilation openings clear.
When two channels discharge simultaneously, each channel still has its own rating; the combined description should not be misread as a single channel’s capability. Confirm the correct mode on both batteries and avoid assuming that starting a second channel doubles the rate for one pack. A battery with a broken balance lead or swollen casing is not a suitable candidate for routine storage discharge and requires separate safe handling.
The D300 Plus can be useful for ordinary dual-channel charging while being a poor choice for rapidly discharging a large inventory of fully charged 6S packs. That is a workflow mismatch rather than necessarily a product defect. Evaluate how many batteries your operation actually returns to the shop with high state of charge before selecting equipment.
Safe alternatives for a larger FPV battery fleet
The first solution is planning: charge only as many packs as the session is likely to need, keeping reserve inventory at the manufacturer’s recommended storage state. This reduces the number of full packs you must discharge after a cancellation. The second is to distribute the work across appropriately rated channels or chargers without overloading power circuits. The third, for high-volume professional operators, is to investigate purpose-built protected discharging or energy-recovery equipment with manufacturer-approved connections and clear thermal ratings.
A homemade resistor, car bulb or improvised discharge harness can produce dangerous heat, uncontrolled current or a short circuit. Do not treat such methods as an inexpensive equivalent of engineered battery-management equipment. Lithium packs require correct cell monitoring and termination conditions. Use fire-safe supervision and suitable charging/discharging areas away from combustible materials.
For a buyer, read specifications under the separate headings “charging power,” “discharge power,” “discharge current,” “balance current,” and “supported cell count.” These numbers answer different questions. A charger with a very high charging wattage but only 15 W internal discharge may be excellent for quick turnaround at the flying field but slow for returning dozens of spare batteries to storage condition.
Record battery health and the charging workflow
For regular FPV work, keep a modest log of pack identifier, chemistry, cell count, charge date and any abnormal readings. A pack that repeatedly shows a single cell out of step with the others should not be pushed through repeated aggressive cycles hoping it will become healthy. Inspect cables, connectors and battery casing before every session. The D300 Plus supports multiple battery types, so verify that the selected chemistry and final voltage correspond to the actual pack rather than relying on the previous channel’s setting.
In the workshop, treat “storage complete” as a state verified by the charger, not as a fixed number of minutes. If a pack remains warm or behaves abnormally, follow the manufacturer’s safety instructions. When a job is interrupted by weather, build sufficient turnaround time into the battery plan; rushing an ordinary storage discharge is unnecessary and potentially hazardous.
Once customers understand the 15 W discharge limit, the behaviour stops looking mysterious. The more useful buying question becomes how often they need fast discharge rather than whether a 700 W charger should also remove 700 W from a pack. Matching the tool to that real operational need produces a better purchasing decision.
Frequently asked questions
Why is storage mode much slower than charging?
The charger dissipates discharge energy internally and is rated for much lower discharge power than charge power.
Can I set 16 A discharge because the charger can charge at 16 A?
No. Charging-current and discharge-current limits are different.
Should I discharge through an improvised electrical load?
No. Use properly engineered, protected discharge equipment and manufacturer instructions.
Shop the matching charger at FalconFly
For the exact hardware discussed here, see the Gens Ace iMars D300 Plus Smart Charger in our UAE store. Check your battery chemistry, connector, AC plug and charging requirements before ordering; its 700W DC charging rating does not change the 15W-per-channel internal discharge limit.
Related FalconFly guides
Verified sources
Grepow / Gens Ace: official iMars D300 Plus introduction, December 1, 2025